If there is no system circulation on a Grant Solar Thermal System, heating engineers should check for the following:
Check whether the pump is operating or not (please refer to the manual for the Grant Solar Thermal Pump Station for support here)
If the pump is noisy, this may suggest that there is air in the system
Check whether the pump may be air locked and needs venting - let the pump run and the pump vents itself over time
Check if the valves are closed - ensure that the Flow and Return valves are fully open. If filling or flushing the system, ensure the Filling/Shut off valves are fully open.