GRANT ENGINEERING (UK) LTD -OIL BOILER RANGE - TECHNICAL DETAILS
Revised 21/07/08
CONDENSING RANGE
| Boiler |
Boiler type |
Boiler model |
Set output |
Burner |
Dimensions (mm) |
Weight |
Conventional |
Connection sizes |
Exp vessel |
SEDBUK |
Nozzle |
Pressure |
| range |
kW |
Btu/h |
make/type |
Width |
Height |
Depth |
dry (kg) |
flue |
Flow |
Return |
size (litres) |
Efficiency |
(kerosene) |
(bar) |
| Vortex PRO |
Kitchen/Utility |
15/21 |
21.0 |
71,650 |
Riello RDB2.2 ³ |
348 |
855 |
566 |
104.0 |
100mm dia |
22mm ¹ |
22mm ¹ |
N/A |
93.0 |
0.60/80º EH |
9.0 |
| (front service) |
15/26 |
23.0 |
78,475 |
Riello RDB1 |
470 |
860 |
603 |
112.0 |
100mm dia |
22mm ¹ |
22mm * |
N/A |
95.0 |
0.65/80º EH |
8.5 |
| |
26/36 |
31.5 |
107,500 |
Riello RDB2 |
470 |
900 |
603 |
134.0 |
100mm dia |
28mm ¹ |
28mm * |
N/A |
97.0 |
0.85/80º EH |
9.0 |
| |
36/46 |
41.5 |
142,000 |
Riello RDB2.2 |
470 |
900 |
603 |
134.0 |
100mm dia |
28mm ¹ |
28mm * |
N/A |
92.6 |
1.20/80º S |
8.0 |
| |
46/58 |
52.0 |
177,424 |
Riello RDB3.2 |
563 |
1234 |
786 |
295.0 |
100/125mm ¤ |
1¼" BSP |
1¼" BSP |
N/A |
94.1 |
1.35/80º S |
9.5 |
| |
58/70 |
64.0 |
218,368 |
Riello RDB3.2 |
563 |
1234 |
786 |
299.0 |
100/125mm ¤ |
1¼" BSP |
1¼" BSP |
N/A |
93.6 |
1.65/80º S |
9.5 |
| Utility System |
15/26 |
23.0 |
78,475 |
Riello RDB1 |
470 |
860 |
603 |
127.0 |
100 |
22mm ¹ |
22mm * |
10 |
95.0 |
0.65/80º EH |
8.5 |
| (top service) |
26/36 |
31.5 |
107,500 |
Riello RDB2 |
470 |
900 |
603 |
142.0 |
100 |
28mm ¹ |
28mm * |
12 |
97.0 |
0.85/80º EH |
9.0 |
| |
36/46 |
41.5 |
142,000 |
Riello RDB2.2 |
470 |
900 |
603 |
142.0 |
100 |
28mm ¹ |
28mm * |
16 |
92.6 |
1.20/80º S |
8.0 |
| External Module |
15/21 |
21.0 |
71,650 |
Riello RDB2.2 ³ |
385 |
879 |
943 ² |
117.0 |
Green sys/90 |
22mm ¹ |
22mm ¹ |
10 |
93.0 |
0.60/80º EH |
9.0 |
| |
15/26 |
23.0 |
78,475 |
Riello RDB1 |
505 |
908 |
1005 ² |
157.0 |
Green sys/90 |
22mm ¹ |
22mm ¹ |
12 |
95.0 |
0.65/80º EH |
8.5 |
| |
26/36 |
31.5 |
107,500 |
Riello RDB2 |
505 |
908 |
1005 ² |
174.0 |
Green sys/200 |
28mm ¹ |
28mm ¹ |
16 |
97.0 |
0.85/80º EH |
9.0 |
| |
36/46 |
41.5 |
142,000 |
Riello RDB2.2 |
505 |
908 |
1005 ² |
174.0 |
Green sys/200 |
28mm ¹ |
28mm ¹ |
16 |
92.6 |
1.20/80º S |
8.0 |
| Vortex ECO |
Utility |
15/21 |
18.1 |
61,750 |
Riello RDB2.2 ³ |
430 |
860 |
605 |
103.0 |
100 |
22mm ¹ |
22mm ¹ |
12 |
93.0 |
0.55/80º EH |
7.5 |
| |
21/26 |
22.7 |
77,500 |
Riello RDB2.2 |
430 |
860 |
605 |
103.0 |
100 |
22mm ¹ |
22mm ¹ |
12 |
92.4 |
0.65/80º EH |
8.5 |
| |
26/35 |
30.8 |
105,100 |
Riello RDB2.2 |
470 |
900 |
603 |
121.0 |
100 |
22mm ¹ |
22mm ¹ |
12 |
92.1 |
0.85/80º EH |
9.1 |
| External Module |
15/21 |
18.1 |
61,750 |
Riello RDB2.2 ³ |
505 |
908 |
1005 ² |
135.0 |
Green sys/90 |
22mm ¹ |
22mm ¹ |
12 |
93.0 |
0.55/80º EH |
7.5 |
| |
21/26 |
22.7 |
77,500 |
Riello RDB2.2 |
505 |
908 |
1005 ² |
135.0 |
Green sys/90 |
22mm ¹ |
22mm ¹ |
12 |
92.4 |
0.65/80º EH |
8.5 |
| |
26/35 |
30.8 |
105,100 |
Riello RDB2.2 |
505 |
908 |
1005 ² |
152.0 |
Green sys/200 |
22mm ¹ |
22mm ¹ |
12 |
92.1 |
0.85/80º EH |
9.1 |
| Vortex ECO Wall-hung |
Internal |
12/16 |
14.0 |
47,770 |
Ecoflam MAX1 |
580 |
850 |
322 |
85.7 |
100 |
22mm ¹ |
22mm ¹ |
N/A |
94.9 |
0.40/80º EH |
10.0 |
| |
16/21 |
18.7 |
63,800 |
Ecoflam MAX1 |
580 |
850 |
322 |
85.7 |
100 |
22mm ¹ |
22mm ¹ |
N/A |
93.8 |
0.50/80º EH |
10.0 |
| Internal System |
12/16 |
14.0 |
47,770 |
Ecoflam MAX1 |
580 |
850 |
322 |
92.2 |
100 |
22mm ¹ |
22mm ¹ |
8 |
94.9 |
0.40/80º EH |
10.0 |
| |
16/21 |
18.7 |
63,800 |
Ecoflam MAX1 |
580 |
850 |
322 |
92.2 |
100 |
22mm ¹ |
22mm ¹ |
8 |
93.8 |
0.50/80º EH |
10.0 |
| External |
12/16 |
14.0 |
47,770 |
Ecoflam MAX1 |
635 |
837 |
366 |
92.3 |
Green sys/90 |
22mm ¹ |
22mm ¹ |
N/A |
94.9 |
0.40/80º EH |
10.0 |
| |
16/21 |
18.7 |
63,800 |
Ecoflam MAX1 |
635 |
837 |
366 |
92.3 |
Green sys/90 |
22mm ¹ |
22mm ¹ |
N/A |
93.8 |
0.50/80º EH |
10.0 |
| External System |
12/16 |
14.0 |
47,770 |
Ecoflam MAX1 |
635 |
837 |
366 |
98.8 |
Green sys/90 |
22mm ¹ |
22mm ¹ |
8 |
94.9 |
0.40/80º EH |
10.0 |
| |
16/21 |
18.7 |
63,800 |
Ecoflam MAX1 |
635 |
837 |
366 |
98.8 |
Green sys/90 |
22mm ¹ |
22mm ¹ |
8 |
93.8 |
0.50/80º EH |
10.0 |
| Vortex PRO Combi 'e' |
Kitchen Combi |
21 |
21 |
71,650 |
Riello RDB2.2 ³ |
590 |
860 |
600 |
146.0 |
100 |
22mm ¹ |
22mm ¹ |
10 |
90.2 |
0.60/80º EH |
9.0 |
| |
26 |
26 |
88,700 |
Riello RDB1 |
590 |
860 |
605 |
188.0 |
100 |
22mm ¹ |
22mm ¹ |
12 |
92.2 |
0.75/80º EH |
8.0 |
| |
36 |
36 |
123,700 |
Riello RDB2.2 |
615 |
900 |
605 |
218.0 |
100 |
28mm ¹ |
28mm ¹ |
14 |
94.2 |
1.00/80º EH |
9.1 |
| External Combi |
21 |
21 |
71,650 |
Riello RDB2.2 ³ |
658 |
945 |
966 ² |
147.0 |
Green sys/90 |
22mm ¹ |
22mm ¹ |
10 |
90.2 |
0.60/80º EH |
9.0 |
| |
26 |
26 |
88,700 |
Riello RDB1 |
658 |
945 |
966 ² |
200.0 |
Green sys/90 |
22mm ¹ |
22mm ¹ |
12 |
92.2 |
0.75/80º EH |
8.0 |
| |
36 |
36 |
123,700 |
Riello RDB2.2 |
658 |
945 |
966 ² |
215.0 |
Green sys/200 |
28mm ¹ |
28mm ¹ |
14 |
94.2 |
1.00/80º EH |
9.1 |
IMPORTANT NOTES:
¹ Push-fit connectors supplied with boiler
² Depth of boiler includes flue terminal and terminal guard
³ Burner fitted with internal air adjuster factory set to position ‘C’
* Compression fitting (supplied on boiler connection)
¤ 125mm for Orange flue systems using flexible flue liner – 100mm for combined Orange & Green flue system without flexible flue liner
NON-CONDENSING RANGE
| Boiler |
Boiler type |
Boiler model |
Set output |
Burner |
Width |
Height |
Depth |
Weight |
Conventional |
Connection sizes |
Exp vessel |
SEDBUK |
Nozzle |
Pressure |
| range |
kW |
(Btu/h) |
make/type |
(mm) |
(mm) |
(mm) |
dry (kg) |
flue |
Flow |
Return |
size (litres) |
Efficiency |
(kerosene) |
(bar) |
| Euroflame |
Kitchen/Utility |
50/70 |
17.6 |
60,000 |
Riello RDB1SH |
345 |
812 |
555 |
76.0 |
100mm dia |
1" BSP |
1" BSP |
N/A |
85.3 |
0.60/60º EH |
7.0 |
| (top service) |
70/90 |
23.5 |
80,000 |
Riello RDB1 |
410 |
860 |
600 |
109.0 |
100mm dia |
1" BSP |
1" BSP |
N/A |
85.3 |
0.75/60º EH |
7.0 |
| |
90/120 |
32.2 |
110,000 |
Riello RDB2 |
410 |
860 |
600 |
121.0 |
125mm dia |
1¼" BSP |
1¼" BSP |
N/A |
85.2 |
1.00/80º H |
8.0 |
| Boiler house |
50/70 |
17.6 |
60,000 |
Riello RDB1SH |
345 |
705 |
555 |
55.0 |
100mm dia |
1" BSP |
1" BSP |
N/A |
85.3 |
0.60/60º EH |
7.0 |
| 70/90 |
23.5 |
80,000 |
Riello RDB1 |
425 |
750 |
620 |
100.0 |
100mm dia |
1" BSP |
1" BSP |
N/A |
85.3 |
0.75/60º EH |
7.0 |
| |
90/120 |
32.2 |
110,000 |
Riello RDB2 |
425 |
715 |
620 |
112.0 |
125mm dia |
1¼" BSP |
1¼" BSP |
N/A |
85.2 |
1.00/80º H |
8.0 |
| Kitchen System |
50/90 |
23.5 |
80,000 |
Riello RDB1 |
410 |
860 |
600 |
117.0 |
100mm dia |
22mm ¹ |
1" BSP |
12 |
85.3 |
0.75/60º EH |
7.0 |
| (top service) |
90/120 |
32.2 |
110,000 |
Riello RDB2 |
410 |
860 |
600 |
129.0 |
125mm dia |
28mm ¹ |
11/4" BSP |
12 |
85.2 |
1.00/80º H |
8.0 |
| Multipass |
Kitchen |
50/70 |
20.5 |
70,000 |
Riello RDB1 |
410 |
860 |
605 |
115.0 |
100mm dia |
1" BSP |
1" BSP |
N/A |
85.7 " |
0.60/60º S |
9.0 |
| (front service) |
70/90 |
23.5 |
80,000 |
Riello RDB1 |
410 |
860 |
605 |
117.0 |
100mm dia |
1" BSP |
1" BSP |
N/A |
85.7 " |
0.75/60º EH |
7.0 |
| 90/140 |
36.7 |
125,000 |
Riello RDB2 |
410 |
1080 |
690 |
148.0 |
125mm dia |
1¼" BSP |
1¼" BSP |
N/A |
85.7 " |
1.10/80º EH |
8.5 |
| |
140/160 |
47.0 |
160,000 |
Sterling 90 |
530 |
1200 |
835 |
210.0 |
125mm dia |
1¼" BSP |
1¼" BSP |
N/A |
85.7 " |
1.35/60º S |
8.0 |
| |
160/200 |
58.6 |
200,000 |
Sterling 90 |
530 |
1200 |
835 |
210.0 |
150mm dia |
1¼" BSP |
1¼" BSP |
N/A |
85.7 " |
1.65/60º S |
9.2 |
| Boiler house |
70/90 |
23.5 |
80,000 |
Riello RDB1 |
460 |
720 |
625 |
98.0 |
100mm dia |
1" BSP |
1" BSP |
N/A |
85.7 " |
0.75/60º EH |
7.0 |
| |
90/140 |
36.7 |
125,000 |
Riello RDB2 |
460 |
895 |
655 |
125.0 |
125mm dia |
1¼" BSP |
1¼" BSP |
N/A |
85.7 " |
1.10/80º EH |
8.5 |
| |
140/160 |
47.0 |
160,000 |
Sterling 90 |
550 |
1000 |
765 |
197.0 |
125mm dia |
1¼" BSP |
1¼" BSP |
N/A |
85.7 " |
1.35/60º S |
8.0 |
| |
160/200 |
58.6 |
200,000 |
Sterling 90 |
550 |
1000 |
765 |
197.0 |
150mm dia |
1¼" BSP |
1¼" BSP |
| |